Hi Douglas,
Thanks for your reply. We used different tracers for diagnosis of AD or other neurodegenerative diseases, including PIB, FDG, Flutemetamol and TAU. If an SUV analysis is used, is it done by mri_gtmpvc? Is there any subsequent analysis needed?
This is my mri_gtmpvc command:mri_gtmpvc \--i $SUBJECTS_DIR/sub-QM001/pet/sub-QM001_ses-001_trc-C11PIB_rec-05MINS_run-001_pet.nii.gz \--reg $SUBJECTS_DIR/sub-QM001/pet/sub-QM001_ses-001_trc-C11PIB_rec-05MINS_run-001_pet.reg.lta \--psf 6 \--seg $SUBJECTS_DIR/sub-QM001/mri/gtmseg.mgz \--default-seg-merge \--auto-mask 1 .01 \--mgx .01 \--o $SUBJECTS_DIR/sub-QM001/pet/gtmpvc.output
Is this command okay?
Thanks,Angel
From: freesurfer-bounces@nmr.mgh.harvard.edu <freesurfer-bounces@nmr.mgh.harvard.edu> on behalf of Douglas N. Greve <dgreve@mgh.harvard.edu>
Sent: Wednesday, March 20, 2024 11:27 PM
To: freesurfer@nmr.mgh.harvard.edu <freesurfer@nmr.mgh.harvard.edu>
Subject: Re: [Freesurfer] PetSurfer: Can kinetic modeling be applied to PET data with single frame?you cannot apply kinetic modeling to one frame. What is you ligand? For a one frame acquisition, you usually use an SUV analysis.
On 3/20/2024 12:03 AM, WONG Wan Wa wrote:
External Email - Use Caution
Hi experts,
As stated in the subject, can kinetic modeling be applied to PET data with only one frame? Or we just stop at ROI analysis without kinetic modeling?
Best,Angel
_______________________________________________ Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu MailScanner has detected a possible fraud attempt from "secure-web.cisco.com" claiming to be https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer
_______________________________________________ Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer