As some of the lesion masks are found to be weird, which shows false positive lesions on the brain, I increased the threshold to lower false positive results. The number of lesion volume and the lesion mask did not show the difference between two different thresholded images, though. Is it normal to have lesion volume the same even with a different threshold?
I look forward to hearing from you. Thank you so much for your time and patience.
Best regards,
Krystal
External Email - Use Caution
_______________________________________________External Email - Use Caution
Dear FS experts,
I am testing out which threshold works the best for the image. As I tested 0.3 and 0.9, the lesion masks do show the difference but the measurement is the same. Please see below for your information:
Fig 1. Lesion.mgz with a threshold of 0.3 applied to FLAIR image
Fig 2. Lesions.mgz with a threshold of 0.7 applied to FLAIR image
Do the volume of lesions supposedly different with threshold adjustments?
The following code is what I used for running samseg:
run_samseg --input $FREESURFER_HOME/${i}.nii $FREESURFER_HOME/${i}_flair_reg.nii --pallidum-separate --lesion --lesion-mask-pattern 0 1 --threshold 0.7 --output $SUBJECTS_DIR/${i}_samsegOutput_thold0.7/ --save-posteriors --threads 8Thank you for your attention.
Regards,Krystal