(mri_vol2surf) and then smooth it there (mri_surf2surf or
mris_fwhm).
On 12/12/2017 11:23 AM, John Anderson wrote:
> Dear Dr Bruce, I highly appreciate the response.
> I want to smooth PET volumetric images, when I use
"fslmaths", it
> shifts the signal from the cortex to the underlying
structures. I
> think (depending on wiki) that Freesurfer handles
this issue by
> smoothing on sphere. Which is the recommendded stream
in PETsurfer.
>
> I am wondering if there are any commands within
Freesurfer that can be
> used to smooth volumtric PET images without taking
the average signal
> of the neighboring voxels (like in Gaussian
smoothing).
>
> Also, I have question about mri_fwhm:
> what is the difference between the flags
(--smooth-only; --fwhm). I am
> aware that "mri_fwhm" is very well
explained in FS wiki, but I was
> unable to exactly understand the difference. For
instance when I use
> the flag --smooth-only the output image is somehow
similar to the
> input image. Is Gaussian in this cases ~1
mri_fwhm (and mris_fwhm) where initially developed to
measure the FWHM
but I extended it to be able to apply smoothing (--fwhm)
as well as
measure the smoothness. The --smooth-only says to not do
the FWHM
estimate (just smooth it).
>
> Thanks in advance!
> J
>
>
>
>
>
>
>> -------- Original Message --------
>> Subject: Re: [Freesurfer] cortical thickness
smoothing
>> Local Time: December 12, 2017 10:38 AM
>> UTC Time: December 12, 2017 3:38 PM
>> From: fischl@nmr.mgh.harvard.edu
>> To: John Anderson <John.anderso@protonmail.com>,
Freesurfer support
>> list <freesurfer@nmr.mgh.harvard.edu>
>>
>> Hi John
>>
>> I don't think fslmaths takes a surface topology so
they won't be the same
>> (mri_surf2surf smooths within the surface and
fslmaths smooths in the
>> volume I believe)
>>
>> cheers
>> Bruce
>>
>>
>> On Tue, 12 Dec 2017, John Anderson wrote:
>>
>> Dear
Freesurfer experts,
>> I ran
recon-all with the flag -qcache to generate smoothed
>> cortical thickness maps.
>> In
order to check how the flag "-qcache" is smoothing the
>> cortical thickness data. I looked into the
>> file
$subj_dir/scripts/recon-all.log" which showed that the
>> following command was applied:
>> mri_surf2surf --prune --s fsaverage --hemi lh --fwhm 5--sval
>> lh.sulc.fsaverage.mgh --tval
>> lh.sulc.fwhm5.fsaverage.mgh --cortex
>> Please
I want to know whether the flag "--fwhm" applies similar
>> smoothing method to the smoothing
>> output
of the command "fslmaths":
>> fslmaths <input_image.nii> -kernel gauss 2.213 -fmean
>> <output_image.nii> -odt float
>> I want
to smooth two different modality-images using the cortical
>> thickness smoothing method.
>> Thank
you for any advice!
>> John
>>
>>
>>
>> The information in this e-mail is intended only
for the person to
>> whom it is
>> addressed. If you believe this e-mail was sent
to you in error and
>> the e-mail
>> contains patient information, please contact the
Partners Compliance
>> HelpLine at
>> http://www.partners.org/complianceline . If the e-mail was sent to
>> you in error
>> but does not contain patient information, please
contact the sender
>> and properly
>> dispose of the e-mail.
>
>
>
> _______________________________________________
> Freesurfer mailing list
> Freesurfer@nmr.mgh.harvard.edu
> https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer
--
Douglas N. Greve, Ph.D.
MGH-NMR Center
Phone Number: 617-724-2358
Fax: 617-726-7422
Bugs: surfer.nmr.mgh.harvard.edu/fswiki/BugReporting
FileDrop: https://gate.nmr.mgh.harvard.edu/filedrop2
www.nmr.mgh.harvard.edu/facility/filedrop/index.html
Outgoing: ftp://surfer.nmr.mgh.harvard.edu/transfer/outgoing/flat/greve/
_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer