Hi Yujing,
thank you for your help! But I think, this is only the affine registration?
Is it possible that I can use the same transformation, by which e.g. aseg.mgz-atlas is transformed into the native space of a given subject?
The volume-dataset of the subcortical regions matches quite well with the subcortical structure of each subject, but I think that this can't be achieved by an affine transformation only.

Best regards,
Peter




On Fri, Nov 17, 2023 at 3:57 PM Huang, Yujing <YHUANG43@mgh.harvard.edu> wrote:

Hi Peter,

 

Here is an example to convert from native space to MNI305 (fsaverage) in  MailScanner has detected a possible fraud attempt from "secure-web.cisco.com" claiming to be https://surfer.nmr.mgh.harvard.edu/fswiki/mri_vol2vol

 

      mri_vol2vol --mov orig.mgz

     --targ $FREESURFER_HOME/average/mni305.cor.mgz

     --xfm transforms/talairach.xfm

     --o orig-in-mni305.mgz

   

In your case, I think you also need ‘—interp nearest’ to convert segmentation.

 

To convert from fsaverage to native space of a subject, can you try the following? I used bert as an example.

     mri_vol2vol

       --mov bert/mri/orig.mgz

       --targ fsaverage/mri/aseg.mgz

       --xfm transforms/talairach.xfm

       --inv

       --o aseg-from-mni305.mgz

       --interp nearest

 

Best,

 

Yujing

 

From: freesurfer-bounces@nmr.mgh.harvard.edu <freesurfer-bounces@nmr.mgh.harvard.edu> On Behalf Of P Pieperhoff
Sent: Thursday, November 16, 2023 12:07 PM
To: Freesurfer support list <freesurfer@nmr.mgh.harvard.edu>
Subject: [Freesurfer] Transformation of volume images

 

        External Email - Use Caution        

Dear developers,

 

please, may I ask you how I can transform volume images (containing discrete region labels) from the fsaverage space into the space of a given subject, and vice-versa?

 

I tried the following command:

mri_vol2vol --interp nearest --mov fsaverage/mri/aseg.mgz  --o test_mask.mgz    --s test001  --targ test001/mri/orig.mg

 

or

mri_vol2vol   --interp nearest --mov fsaverage/mri/aseg.mgz  --o test_mask.mgz    --targ  test001/mri/T1.mgz  --lta  test001/mri/transforms/talairach.lta --m3z talairach.m3z
--s test001

 

but there was always a large mismatch between the transformed images and the target image.

 

Best regards,

Peter

_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
MailScanner has detected a possible fraud attempt from "secure-web.cisco.com" claiming to be https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer
The information in this e-mail is intended only for the person to whom it is addressed.  If you believe this e-mail was sent to you in error and the e-mail contains patient information, please contact the Mass General Brigham Compliance HelpLine at MailScanner has detected a possible fraud attempt from "secure-web.cisco.com" claiming to be https://www.massgeneralbrigham.org/complianceline <MailScanner has detected a possible fraud attempt from "secure-web.cisco.com" claiming to be https://www.massgeneralbrigham.org/complianceline> .