Hello FreeSurfer Developers and Community,
I am working with an axial T1-weighted post-contrast MRI, with an original voxel size of 1.5 mm. I resampled this MRI in 3D Slicer using B-Spline interpolation and then saved it as a mgz file. After running recon-all on this resampled file, I noticed that the right hemisphere抯 segmentation and parcellation are flawed. Also, considering the age and health situation of this patient, i believe the WM hypointensities are overestimated in the left hemisphere.
I am using the following version of FreeSurfer: freesurfer-macOS-darwin_x86_64-7.4.1-20230614-7eb8460.The command line was:recon-all -s 12th_recon_output -i input.mgz -all -parallel -openmp 12
I抳e attached the recon-all log file, a screenshot from Freeview to illustrate the issue, and mri_info file. I would greatly appreciate any guidance, troubleshooting advice, or suggestions on what might have gone wrong and how to correct this issue.
Thank you in advance for your help!
Best regards,Nima
_______________________________________________ Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer