External Email - Use Caution
Hi Star
what do you mean by "outside the inflated surfaces"? Can you send an
image? The inflated surface should not be viewed overlaid on a slice as
it no longer corresponds directly to the underlying MRI. You should
visualize the ?h.white and ?h.pial surfaces instead to assess accuracy
cheers
Bruce
On
Thu, 3 Jan 2019, xi star wrote:
>
> External Email - Use Caution
>
> I'm a beginner on fs. my data was done with no error in all three
> parts of recon-all (autorecon1 2 & 3), and I've checked the surfaces each
> time.
> However, I found the pial and wm of part of the frontal and parietal
> lobel was outside the inflated surfaces. As you can see in the attachment.
> I wonder what's wrong with the data or how i can find and fix the
> problem. I really puzzled and want your help
> Best wish,
> Star
>
>
>
>_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer