Hi,
I am getting an error message while trying to convert the SIEMENS IMA to MGZ:

siemensRead(): file rows (30067) not divisible by image rows (18771)

It looks like i managed to do a similar conversion before, so I wonder if there is something I need to add to the command line for this special case that I forget?

thanks! 


On 9/23/07, Bruce Fischl <fischl@nmr.mgh.harvard.edu> wrote:
Hi Martin,

you can do this with mri_convert using -rl $SUBJECT_ID/mri/orig/001.mgz
(reslice like this volume) and -rt nearest (resample type nearest neighbor)
I think. Check the help if this is wrong. It will need to resample though.

cheers,
Bruce


On Sun, 23 Sep 2007, Martin Kavec
wrote:

> Hi,
>
> how can I map the aparc+aseg.mgz back to $SUBJECT_ID/mri/orig/001.mgz, but
> without suffering from interpolation?
>
> Thanks,
>
> Martin
> _______________________________________________
> Freesurfer mailing list
> Freesurfer@nmr.mgh.harvard.edu
> https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer
>
>
>
_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu