Hi Eugenio,
just to confirm I understand the currently available options. There are two multispectral strategies (MPRAGE + high res 2D T2, or MPRAGE + 3D FLAIR). It would be great to see if the combo option improves things even further for the subfields (MPRAGE + high res 2D T2 + 3D FLAIR). Is that option at all possible with the available FS version or in the works?
Best,
Jorge
On 05/09/2016 16:13, Iglesias, Eugenio wrote:
The same one; just change the input file and the analysis ID
- T2: recon-all -s mySubject -hippocampal-subfields-T1T2 myT2scan.nii.gz T2
- FLAIR: recon-all -s mySubject -hippocampal-subfields-T1T2 myFLAIRscan.nii.gz FLAIR
Cheers,
/Eugenio
Juan Eugenio IglesiasSenior Research Fellow
Translational Imaging Group
University College London
http://www.jeiglesias.com
http://cmictig.cs.ucl.ac.uk/
On 5 Sep 2016, at 15:10, Vaz pandolfo, Renata <rvp8@njit.edu> wrote:
Dear FS experts,I have a question about the "segmentation with an additional scan - multispectral segmentation" on the hippocampal sf segmentation, FS dev. 6.0.For controls on which I had already run recon-all -all, I added the T2 sequence with the following command:recon-all -s <subject_name> \ -hippocampal-subfields-T1T2 <file name of additional scan> <analysisID>Now, if I want to do the same thing with FLAIR as the additional input, which flag should I use? Thank you,Renata
_______________________________________________ Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu https://mail.nmr.mgh.harvard. edu/mailman/listinfo/ The information in this e-mail is intended only for the person to whom it is addressed. If you believe this e-mail was sent to you in error and the e-mail contains patient information, please contact the Partners Compliance HelpLine at http://www.partners.org/freesurfer complianceline . If the e-mail was sent to you in error but does not contain patient information, please contact the sender and properly dispose of the e-mail.
-- Jorge Jovicich, Ph.D. MR Lab Head Center for Mind/Brain Sciences University of Trento, Via delle Regole, 101 38100 Mattarello (TN) Italy Telephone: +39-0461-28 3064 Fax: +39-0461-28-3066 Email: jorge.jovicich@unitn.it MRI Methods Group: http://r.unitn.it/en/cimec/mri CIMEC: http://www.cimec.unitn.it/