Dear Jorge,

In my case I am using either T1+T2 or T1+FLAIR.
I had no intention of using all three at once, but now I am also wondering if this would be an improvement.

Cheers,

Renata

On Mon, Sep 5, 2016 at 4:54 PM, Jovicich, Jorge <jorge.jovicich@unitn.it> wrote:

Hi Eugenio,

just to confirm I understand the currently available options. There are two multispectral strategies (MPRAGE + high res 2D T2, or MPRAGE + 3D FLAIR). It would be great to see if the combo option improves things even further for the subfields (MPRAGE + high res 2D T2 + 3D FLAIR). Is that option at all possible with the available FS version or in the works?

Best,

    Jorge


On 05/09/2016 16:13, Iglesias, Eugenio wrote:
The same one; just change the input file and the analysis ID

- T2:       recon-all -s mySubject -hippocampal-subfields-T1T2 myT2scan.nii.gz  T2

- FLAIR: recon-all -s mySubject -hippocampal-subfields-T1T2 myFLAIRscan.nii.gz  FLAIR

Cheers,

/Eugenio

Juan Eugenio Iglesias
Senior Research Fellow
Translational Imaging Group
University College London
http://www.jeiglesias.com
http://cmictig.cs.ucl.ac.uk/


On 5 Sep 2016, at 15:10, Vaz pandolfo, Renata <rvp8@njit.edu> wrote:

Dear FS experts,

I have a question about the "segmentation with an additional scan - multispectral segmentation" 
on the hippocampal sf segmentation, FS dev. 6.0.
For controls on which I had already run recon-all -all, I added the T2 sequence with the following 
command:
recon-all -s <subject_name> \
-hippocampal-subfields-T1T2 <file name of additional scan> <analysisID>

Now, if I want to do the same thing with FLAIR as the additional input, which flag should I use?

Thank you,
Renata



_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer


The information in this e-mail is intended only for the person to whom it is
addressed. If you believe this e-mail was sent to you in error and the e-mail
contains patient information, please contact the Partners Compliance HelpLine at
http://www.partners.org/complianceline . If the e-mail was sent to you in error
but does not contain patient information, please contact the sender and properly
dispose of the e-mail.

-- 
Jorge Jovicich, Ph.D.

MR Lab Head
Center for Mind/Brain Sciences
University of Trento,
Via delle Regole, 101
38100 Mattarello (TN)
Italy

Telephone: +39-0461-28 3064
Fax: +39-0461-28-3066
Email: jorge.jovicich@unitn.it
MRI Methods Group: http://r.unitn.it/en/cimec/mri
CIMEC: http://www.cimec.unitn.it/