I have a scan where the aseg completely missed the bilateral frontal poles. After learning from the videos I added control points (points that were not 110) in a hope to expand the white matter surface. But after adding control points and rerunning aurorecon, still i do not see anychanges. i have attached a screenshot here. What is the error? Can this be fixed or should I discard it?
Dr. Rakshathi Basavaraju (M.D. Psychiatry)Assistant Professor (Department of Health Research-sponsored return-home research fellowship)Principal Investigator - OPCINSSDepartment of PsychiatryNational Institute of Mental Health and Neurosciences (NIMHANS)Bengaluru, Karnataka, India-560029Phone: +91-9480829898/+91-80-26972156/+91-80-26995320