Hi Jonathan,

is this in cross sectional processing or in longitudinal?

One thing I notice is significant motion artifacts (ringing), which seem to lead to underestimation of WM, also you could fine tune the skull strip.

Best, Martin

On Jun 28, 2013, at 10:19 AM, Jonathan Holt <whatsdac@umich.edu> wrote:

Hi all,

I'm having a bit of trouble with one particular subject for which we brains for 4-5 different time points. The pial surface is consistently misplaced in the same area, see attached main/aux volume images. I'm hesitant to manually replace the white matter myself as I fear it wouldn't be as accurate. Suggestions on other methods to fix this?

The problem is always in the LH temporal right around the lateral inferior ventricle and the fusiform and other subcortical structures. 


<Screen Shot 2013-06-28 at 10.18.59 AM.png><Screen Shot 2013-06-28 at 10.14.50 AM.png>_______________________________________________