Dear Douglas, I don't use image compression. The series are new to me, I see that the images uses a multiframe encoding, there is 63 directions each direction encoded in a sigle image like a BOLD EPI sequence

I will check again all the series

Thanks for the reply

John Ochoa
Universidad de Antioquia

On Wed, Feb 22, 2012 at 1:36 PM, Douglas N Greve <greve@nmr.mgh.harvard.edu> wrote:
It sounds like something went wrong with the conversion to nifti. Do you use image compression? Are you sure that the series is the correct one?
doug

John Fredy wrote:
Hello all,

I am trying to use a set of dti data from a Magnetom Skyra 3T. I use the dt_recon process with data from another siemens of 1.5T without problems. With the Skyra 3T I have the following error in the log file:

MRIresample(): error inverting matrix; determinant is nan, matrix is:

Can someone help me with this problem?

Thanks in advance

John Ochoa
Universidad de Antioquia
------------------------------------------------------------------------

_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer

--
Douglas N. Greve, Ph.D.
MGH-NMR Center
greve@nmr.mgh.harvard.edu
Phone Number: 617-724-2358 Fax: 617-726-7422

Bugs: surfer.nmr.mgh.harvard.edu/fswiki/BugReporting
FileDrop: www.nmr.mgh.harvard.edu/facility/filedrop/index.html



The information in this e-mail is intended only for the person to whom it is
addressed. If you believe this e-mail was sent to you in error and the e-mail
contains patient information, please contact the Partners Compliance HelpLine at
http://www.partners.org/complianceline . If the e-mail was sent to you in error
but does not contain patient information, please contact the sender and properly
dispose of the e-mail.