Dear experts,

I have reprocessed my groups of subjects (originally processed by v5.3) by v6.0. I am using -FLAIRpial for pial surface refinement.

I have noticed that the pial surfaces in v6.0 after -FLAIRpial are positioned much more externally in comparison to -FLAIRpial in v5.3. The v6.0 version includes to pial sheet much more partial volume voxels in comparison to v5.3.

In contrast to v5.3, where the surfaces after -FLAIRpial were mostly internally with respect to pial surfaces determined by T1, in v6.0 there are many regions where the pial surfaces after -FLAIRpial are placed much externally with respect to pial surfaces determined by T1.

See the screenshot (red surfaces are pial surfaces after -FLAIRpial with v6.0, yellow are surfaces after -FLAIRpial with v.5.3).

I have used -nsigma_above 8 in mris_make_surfaces to prevent excluding some cortical regions with high signal intensity but this I used consistently in both versions so it should not be the reason of difference.

I have uploaded the subject processed both by 5.3 and 6.0 version to your server, files FLAIRpial_v5.3.tar.gz and FLAIRpial_v6.0.tar.gz.

Could you please look at my data and check whether the pial surfaces after -FLAIRpial in v6.0 look OK from your perspective?

Regards,

Antonin Skoch