input /Volumes/schnyer/Makenna/DODADNI/BIDS/derivatives/tracula/sub-0003107/dlabel/anatorig/aparc+aseg.nii.gz
frame 0
nErode3d 2
nErode2d 0
output /Volumes/schnyer/Makenna/DODADNI/BIDS/derivatives/tracula/sub-0003107/dlabel/anatorig/aparc+aseg_mask.nii.gz
Binarizing based on threshold
min 0.5
max +infinity
binval 1
binvalnot 0
fstart = 0, fend = 0, nframes = 1
Found 1169534 values in range
Dilating 4 voxels in 3d
Eroding 2 voxels in 3d
Counting number of voxels in first frame
Found 1609388 voxels in final mask
Writing output to /Volumes/schnyer/Makenna/DODADNI/BIDS/derivatives/tracula/sub-0003107/dlabel/anatorig/aparc+aseg_mask.nii.gz
Count: 1609388 1609388.000000 16777216 9.592700
mri_binarize done
printf: illegal option -- -
usage: printf format [arguments ...]
mri_binarize --i /Volumes/schnyer/Makenna/DODADNI/BIDS/derivatives/t1prep/sub-0003107/mri/aparc+aseg.mgz --o /Volumes/schnyer/Makenna/DODADNI/BIDS/derivatives/tracula/sub-0003107/dlabel/anatorig/aparc+aseg+thalnuc.nii.gz
ERROR: must specify minimum and/or maximum threshold or match values
mri_concat --i /Volumes/schnyer/Makenna/DODADNI/BIDS/derivatives/tracula/sub-0003107/dlabel/anatorig/aparc+aseg+thalnuc.nii.gz --i /Volumes/schnyer/Makenna/DODADNI/BIDS/derivatives/t1prep/sub-0003107/mri/ThalamicNuclei.v12.T1.FSvoxelSpace.mgz --max --o /Volumes/schnyer/Makenna/DODADNI/BIDS/derivatives/tracula/sub-0003107/dlabel/anatorig/aparc+aseg+thalnuc.nii.gz
ninputs = 2
Checking inputs
error: niiRead(): error opening file /Volumes/schnyer/Makenna/DODADNI/BIDS/derivatives/tracula/sub-0003107/dlabel/anatorig/aparc+aseg+thalnuc.nii.gz
ERROR: reading /Volumes/schnyer/Makenna/DODADNI/BIDS/derivatives/tracula/sub-0003107/dlabel/anatorig/aparc+aseg+thalnuc.nii.gz
mri_binarize --i /Volumes/schnyer/Makenna/DODADNI/BIDS/derivatives/t1prep/sub-0003107/mri/aparc+aseg.mgz --match 2 41 7 46 172 177 77 --o /Volumes/schnyer/Makenna/DODADNI/BIDS/derivatives/tracula/sub-0003107/dlabel/anatorig/White-Matter.nii.gz
Dear Makenna (and rest of users)_______________________________________________
Thanks for spotting this bug, and for bearing with us while we transition to the new, Matlab-free code.
Renaming should be fine for now but we’ll certainly fix this on our end ASAP.
Kind regards,
On Jul 28, 2022, at 18:15, Makenna B McGill <makennamcgill@utexas.edu> wrote:
Hi FreeSurfer Developers,_______________________________________________
I'm trying to run TRACULA in FreeSurfer v7.3 on OS Monterey.
I was unable to download R2014b Runtime on my newer OS, so instead of the segmentThalamicNuclei.sh script, I tried running the newer segmentation tool segment_subregions thalamus (MailScanner has detected a possible fraud attempt from "secure-web.cisco.com" claiming to be https://surfer.nmr.mgh.harvard.edu/fswiki/SubregionSegmentation).
This was successful, but trac-all looks for the ThalamicNuclei.v12.T1.FSvoxelSpace.mgz file, whereas the subregion segmentation produces the file ThalamicNuclei.FSvoxelSpace.mgz.
I'm wondering two things: (1) is the new segmentation tool compatible with trac-all (the wiki says the results will be very close but not identical), and (2) if so, would it be appropriate to rename/link the file so that trac-all can find it, as this user did with the ThalamicNuclei.v13 file (MailScanner has detected a possible fraud attempt from "secure-web.cisco.com" claiming to be https://www.mail-archive.com/freesurfer@nmr.mgh.harvard.edu/msg73065.html)?
Thank you in advance for any suggestions you might have, and please let me know if anything needs clarified.
Best,Makenna
Makenna McGill (she/her)Doctoral Student in Clinical PsychologyUniversity of Texas at Austin
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
MailScanner has detected a possible fraud attempt from "secure-web.cisco.com" claiming to be https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
MailScanner has detected a possible fraud attempt from "secure-web.cisco.com" claiming to be https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer
The information in this e-mail is intended only for the person to whom it is addressed. If you believe this e-mail was sent to you in error and the e-mail contains patient information, please contact the Mass General Brigham Compliance HelpLine at MailScanner has detected a possible fraud attempt from "secure-web.cisco.com" claiming to be https://www.massgeneralbrigham.org/complianceline <MailScanner has detected a possible fraud attempt from "secure-web.cisco.com" claiming to be https://www.massgeneralbrigham.org/complianceline> .
Please note that this e-mail is not secure (encrypted). If you do not wish to continue communication over unencrypted e-mail, please notify the sender of this message immediately. Continuing to send or respond to e-mail after receiving this message means you understand and accept this risk and wish to continue to communicate over unencrypted e-mail.