Hi Gari,
Does it appear in the right place if you run
tkmedit -f $FSLDIR/data/standard/MNI152_T1_2mm.nii.gz -overlay ROI45.nii
doug
On 07/17/2012 01:20 PM, Garikoitz Lerma Usabiaga wrote:
Hi freesurfer experts,
I want to use a volume based MNI152 ROI in Freesurfer, when I check it
over fsaverage with the following command the ROI is not in the
correct position...:
/
/tkmedit fsaverage T1.mgz -overlay ROI45.nii//-overlay-reg $FREESURFER_HOME/average/mni152.register.dat
/
/
And I have the same problem when I convert it to surface:
cd $SUBJECTS_DIR/fsaverage/surf
mri_vol2surf \
--mov ../../ROI2/ROI45.nii \
--reg $FREESURFER_HOME/average/mni152.register.dat \
--projdist-max 0 1 0.1 \
--interp nearest \
--hemi lh \
--out lh.fsaverage.ROI45.mgh \
--reshape
- Is this a correct way of using it? Should I get proper results or I
am missing anything? and,
- Does it make sense creating a new fsaverage using the
/spm8/canonical/avg152T1.nii, then applying the ROI which is already
in 152 space, and referring the cortical thickness of all the subjects
to this "new fsaverage"? (the functional analysis is being carried in
SPM as well).
Many thanks for your answers,
Gari
_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer
--
Douglas N. Greve, Ph.D.
MGH-NMR Center
greve@nmr.mgh.harvard.eduPhone Number: 617-724-2358
Fax: 617-726-7422
Bugs: surfer.nmr.mgh.harvard.edu/fswiki/BugReporting
FileDrop: www.nmr.mgh.harvard.edu/facility/filedrop/index.html
_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer
The information in this e-mail is intended only for the person to whom it is
addressed. If you believe this e-mail was sent to you in error and the e-mail
contains patient information, please contact the Partners Compliance HelpLine at
http://www.partners.org/complianceline . If the e-mail was sent to you in error
but does not contain patient information, please contact the sender and properly
dispose of the e-mail.