I've isolated the problem to a fsl utility fslreorient2std I used to get the brains to view right-side-up in fslview. I don't get the error when not using this utility. mri_convert is cleared, I think.
Josh
what are your exact mri_convert commands?
doug
> _______________________________________________
On 08/09/2012 06:05 PM, Joshua Lee wrote:
> I used mri_convert to resample my norm.mgz to 0.25 mm iso nii.gz, and
> then again back up to 1mm isotropic space. The resultant image shifted
> up a voxel from the original converted straght to nii.gz. This points
> to the resampling procedure, and not the conversion to different file
> format. Suggestions?
>
> Note: I wanted to hand trace the hippocampus in the norm.mgz, and
> upsampled the norm.mgz to trace on. I traced it, and then downsampled
> to 1mm to compare with Freesurfer segmentation, but found it shifted.
> Josh
>
>
>
> Freesurfer mailing list
> Freesurfer@nmr.mgh.harvard.edu
> https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer
--
Douglas N. Greve, Ph.D.
MGH-NMR Center
greve@nmr.mgh.harvard.edu
Phone Number: 617-724-2358
Fax: 617-726-7422
Bugs: surfer.nmr.mgh.harvard.edu/fswiki/BugReporting
FileDrop: www.nmr.mgh.harvard.edu/facility/filedrop/index.html
_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer
The information in this e-mail is intended only for the person to whom it is
addressed. If you believe this e-mail was sent to you in error and the e-mail
contains patient information, please contact the Partners Compliance HelpLine at
http://www.partners.org/complianceline . If the e-mail was sent to you in error
but does not contain patient information, please contact the sender and properly
dispose of the e-mail.