Dear all,<screenshot3.png>_______________________________________________
I've looked a little bit further into why LGI fails for fsaverage. I previously tried simply running recon-all -s fsaverage-localGI but the script exited with errors after a good while. More importantly for me, the lh.pial-outer-smoothed surface, which I am after, did not look right.
It seems that the first step, mris_fill, produces a volume that does not look very much like a brain anymore (cf. attached screenshot). Any idea why that would happen?
Thanks,
Pierre
--Pierre Mégevand, MD, PhDPLOS Neuro Community editor - Follow us on TwitterPostdoc @ Feinstein Institute for Medical Research (NY, USA)
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer