Hi,
I'm having trouble co-registering a bunch of subjects whose T1 is left-right reversed. While the orientation of the structural file in the NIfTI header is LIA and the orientation of the functional volume is LAS, visual inspection shows that the structural is
left-right reversed. I then followed the steps outlined in
https://surfer.nmr.mgh.harvard.edu/fswiki/LeftRightReversal to rerun the reconstruction and re-registered the subject but the registration mincost value is still hovering around 0.9 even with the left-right reversed structural.
I've tried running registration with SPM and FSL; neither method is able to register these subjects properly.
With --init-fsl I get the following:
WARNING: initial G-W contrast is negative, but expecting positive.
If the mov data has a T1 contrast, re-run with --T1
and with --init-spm I get:
WARNING: bad orientation matrix (determinant = 0) in nifti1 file ...
... continuing.
At this point I'm out of ideas to try out. This issue is occurring for over 170 subjects (data collected outside Martinos using non-siemens scanners).
Any help would be much appreciated!
Thanks,
Afsana
______________________________
Afsana Afzal
Clinical Research Coordinator
Massachusetts General Hospital
Division of Neurotherapeutics
Department of Psychiatry: Neurosciences
149 13th St, Room 2612
Charlestown, MA 02129
Phone: 617-643-5129
Fax: 617-726-4078