Dear Emily,

similar errors I usually try to correct by editing wm.mgz (fill the spots by intensity 255). But it does not work always (mainly when the hypointensities are of large extent, it often does not help either).

Antonin


Hi Emily
it's going to be tough to get it past the gray matter lesions. If you have labels we could implement something to fill them in with surrounding tissue intensities I suppose, but we don't have anything at the moment
sorry
Bruce
On Wed, 31 Oct 2018, Emily Schwartz wrote:
        External Email - Use Caution        

Hi Freesurfer team,

I was wondering if there is a way to edit incorrect surfaces due to lacunes? As 
you can see in the
image the surfaces are incorrect. I tried editing the aseg, but this did not 
work. I have attached
both images in the coronal and axial view as well as FLAIR (obviously there are 
other errors that
need to be fixed in this subject as well).

I am using version 6.0 
(freesurfer-Linux-centos6_x86_64-stable-pub-v6.0.0-2beb96c).

Any guidance is appreciated.

Thank you,

Emily

Emily Schwartz, B.A.
Research Assistant
Department of Neurology -- Cognitive and Motor Aging
Albert Einstein College of Medicine