Hi Doug,
Sorry for interrupting you again with this topic but recently we changed couple of parameters in our MRA to increase our chance or detecting veins. The problem is that, bbregister can not register the MRA volume to T1 scans anymore.
As an example, here you can see the old version of our MRA and how good it was when we used T1+pial registeration:
tkregister2 --mov /cluster/tootell/pitcairn/1/shahin/ColorPrj/MRA_Study/Sbj/auil_2/MRA_500_pre_contrast/010/001_nu.nii --reg /cluster/tootell/pitcairn/1/shahin/ColorPrj/MRA_Study/Sbj/auil_2/MRA_500_pre_contrast/010/register_t1_pial.dat --surf
And here, you can see the new one:
tkregister2 --mov /cluster/tootell/pitcairn/1/shahin/ColorPrj/MRA_Study/Sbj/auil_2/MRA_TOF_2D_500_fa70_cor/018/001_nu.nii --reg /cluster/tootell/pitcairn/1/shahin/ColorPrj/MRA_Study/Sbj/auil_2/MRA_TOF_2D_500_fa70_cor/018/register_t1_pial.dat --surf
Now I have two questions:
1) Is there anyway to improve this registration?
2) Since I collect both MRA types in one session, can I use the good volume (or registrations) to help registering the second volume? I actually used --init-reg but it did not help.
Regards