Thank you Bruce!
I would like to segment a set of caudates into head and body and then obtain the real volume of these two parts. The procedure that I am applying is the following:
1.- Applying the standard recon-all process
2.- Extracting the "conformed" voxel geometry caudate with the following command:
./mri_extract_label $SUBJECTS_DIR/$subj/mri/aseg.mgz 11 $PROJDIR/$subj.nii.gz
3.- Segmenting the caudates into head and body
4.- Transforming the head/body into the native sapece with the following command:
mri_vol2vol --mov Head_Left-Caudate.mgz --targ rawavg.mgz --regheader --o Head_Left-Caudate-in-rawavg.mgz
5.- Voxel counting
Would it be correct?
Thank you in advance,
Yolanda
2011/2/10 Bruce Fischl
<fischl@nmr.mgh.harvard.edu>
Hi Yolanda,
the first command maps the aseg from the "conformed" voxel geometry back to the voxel geometry on the scanner, and the second extracts the caudate from that volume. If you want the caudate in the conformed space, just use aseg.mgz in the mri_extract_label command instead of aseg-in-rawavg.mgz
cheers
Bruce
On Thu, 10 Feb 2011, Yolanda Vives wrote:
Dear freesurfer's,
I have run a conventional recon-all process and I am interested in isolating
the caudate from my subjects. I have applied the following commands:
*./mri_label2vol --seg $SUBJECTS_DIR/$subj/mri/aseg.mgz --temp
$SUBJECTS_DIR/$subj/mri/rawavg.mgz --o
$SUBJECTS_DIR/$subj/mri/aseg-in-rawavg.mgz --regheader
$SUBJECTS_DIR/$subj/mri/aseg.mgz
*
*./mri_extract_label $SUBJECTS_DIR/$subj/mri/aseg-in-rawavg.mgz 11
$PROJDIR/$subj.nii.gz
*
I had seen in the wiki that these commands should be used when we need the
images in native space. ¿Does it mean that my caudates are "denormalized" or
on the contrary, that the images have only been resliced to the original
size? If it is the second case, how could I obtain the caudates from the
original image?
Thank you for your help,
Yolanda
The information in this e-mail is intended only for the person to whom it is
addressed. If you believe this e-mail was sent to you in error and the e-mail
contains patient information, please contact the Partners Compliance HelpLine at
http://www.partners.org/complianceline . If the e-mail was sent to you in error
but does not contain patient information, please contact the sender and properly
dispose of the e-mail.
--
Yolanda Vives
PIC (Port d'Informació Científica)
Campus UAB, Edificio D
E-08193 Bellaterra, Barcelona
Telf. +34 93 586 8232
http://www.pic.es