External Email - Use Caution
Hello,
I am testing SAMSEG on my group of MS patients. Unfortunately, even when
dropping threshold to 0.005 I have large number of false negative lesions
left behind by SAMSEG (80% in about 75 cases I tried), which are clearly
visible lesions. I ran/checked registration between inputs, which is
typically very good to excellent. Images are all 3D acquisitions , mprage,
flair, and t2 with ~1 mm3 isotropic voxel. Here is the command, which I ran:
run_samseg --input mprage_reg.nii.gz flair.nii.gz t2_reg.nii.gz
--pallidum-separate --lesion --lesion-mask-pattern 0 1 1 --threshold 0.005
--output samseg_threshold_0.005
and example of the lesion in occipital white matter in sagittal and axial
orientations.
[image: image.png]
[image: image.png]
I would very much appreciate any leads as to how to improve the
segmentation.
Thanks,
Martin