On 11/29/2021 11:55 AM, Alexopoulos, Dimitrios wrote:
External Email - Use Caution
A quick question.
Is it feasible or even possible to edit the aseg.mgz using another program (i.e. ITK-snap after converting to nifti), and rerunning the pipeline using the revised aseg as input
To regenerate volumes and surfaces?
I think that should work. Edit the aseg.presuf.mgz, then run -autorecon2-noaseg -autorecon3
Do WM edits need to need to be completed on the WM.mgz and/or using Control Points?
I'm not sure what you mean here. WM edits can only be done on wm.mgz (or filled.mgz for 7.2+).
Jim
The materials in this message are private and may contain Protected Healthcare Information or other information of a sensitive nature. If you are not the intended recipient, be advised that any unauthorized use, disclosure, copying or the taking of any action in reliance on the contents of this information is strictly prohibited. If you have received this email in error, please immediately notify the sender via telephone or return mail.