you can run bbregister using the b=0 image as input. The final cost function value should beless than .9, if it is more than that then it probably means you have an LR flip.
doug
On 07/11/2013 03:52 PM, Barron, Daniel S wrote:
Dear Freesurfers,
I am trying to perform probabilistic tractography (FSL Probtrackx) between seed and target VOIs made with Freesurfer's recon-all (T1) and dt_recon (DW) pipelines.
I have the original T1 DICOMs, however, I only have the DW NIFTI image volumes. I do not know how the DW DICOMS were converted to NIFTI and am worried about L-R flipping.
Within Mango, I have found the T1 images converted with mri_convert are (X+,Y-,Z+). The DW NIFTI is (Y-,Z-,X-). mri_info gives me a lot of information that, unfortunately, I do not entirely understand.
Can you recommend a way for me to verify consistent orientation in both my T1 and DW images? Thank you!
Cheers, Daniel
Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer