Hi Gonzalo
is it multi-echo? Phase and mag? You need to find out before you can process it properly. You can extract the frames via:
mri_convert -nth <frame #> <input dicom> <output.mgz>
cheers Bruce
On Wed, 3 Sep 2014, Gonzalo Rojas Costa wrote:
Hi:
I don't know.... it is an mprage got in our center using a Siemens Avanto equipment.... freesurfer specify that the images has two nframes and for that reason freesurfer could not process it...
Sincerely
Gonzalo Rojas Costa
Hi Gonzalo
what is in the two frames? Bruce On Tue, 2 Sep 2014, Gonzalo Rojas Costa wrote:
Hi:
I have an mprage image with nframes = 2... how >>can I convert it to use
it in
freesurfer ?...
Sincerely,
Gonzalo Rojas Costa