Hi Angela,
this may just be a visualization artifact of the resampling to RAS coords. You can try:
view->anatomical sampling->main volume->slice
which will show the raw (unoriented) data, or
view->anatomical resampling->main volume->trilinear
which will use trilinear interpolation instead of nearest neighbor.
cheers, Bruce
On Wed, 4 Feb 2009, Angela Wang wrote:
I am using mri_convert to convert some MR images in dicom format to 001.mgz. When I view 001.mgz, using tkmedit, each transaxial slice looks like it is pieced together from the wrong slice of the original transaxials. As I progress from one slice to the next, this band moves across the image.
It shouldn't look like this, should it?. Is there something I can do to prevent this when converting to mgz format?
Angela