Hi Bruce,
Thanks for the reply, below is a couple of sentences from the recon-all.log
reading initial pial vertex positions from white.preaparc...
mean border=65.6, 300 (300) missing vertices, mean dist 2.2 [2.0 (%0.1)->3.2 (%99.9))]
%21 local maxima, %44 large gradients and %29 min vals, 639 gradients ignored
perforing initial smooth deformation to move away from white surface
tol=1.0e-04, sigma=2.0, host=hpc17, nav=16, nbrs=2, l_surf_repulse=1.000, l_tspring=1.000, l_nspring=0.500, l_intensity=0.200, l_curv=1.000
mom=0.00, dt=0.05.
I also attached a screenshot of the log.
Is there a place I should upload the files?
Thanks,
Jasmin
On Wed, May 31, 2017 at 12:28 PM, Bruce Fischl fischl@nmr.mgh.harvard.edu wrote:
Hi Jasmin
typically that means there is a big topological defect, which definitely can be caused by motion. What is the last couple of lines of the recon-all.log file of one of the subjects? Can you upload an image we can look at?
cheers Bruce
On Wed, 31 May 2017, Jasmin Alves wrote:
Hello,
I have used FS6.0 to do recon-all on about 57 brains, but for some reason, recon-all is not working on some brains, recon-all is not able to get past "Automatic topology fixer", after the command has been running for 24 hours.
Is it possible there is too much motion in the image? Or does FS6.0 possibly take longer to complete for some brains?
Thanks, Jasmin
-- Jasmin Alves Doctoral Candidate Medical Biology Graduate Program University of Southern California jalves@usc.edu
Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu https://urldefense.proofpoint.com/v2/url?u=https-3A__mail. nmr.mgh.harvard.edu_mailman_listinfo_freesurfer&d=DwIBAg&c= clK7kQUTWtAVEOVIgvi0NU5BOUHhpN0H8p7CSfnc_gI&r=LH_W279i0KTyqa6rNRHLug&m= WKDQAULkieLjxSoEKmbYe3vl8MelA4BdRVo3y7hhYtM&s= kd6PbBhNyCt1A17Nz3F8PBlHrz3uOwKoafDjYtq4xKQ&e=
The information in this e-mail is intended only for the person to whom it is addressed. If you believe this e-mail was sent to you in error and the e-mail contains patient information, please contact the Partners Compliance HelpLine at https://urldefense.proofpoint.com/v2/url?u=http-3A__www. partners.org_complianceline&d=DwIBAg&c=clK7kQUTWtAVEOVIgvi0NU5BOUHhpN 0H8p7CSfnc_gI&r=LH_W279i0KTyqa6rNRHLug&m=WKDQAULkieLjxSoEKmbYe3vl8MelA4 BdRVo3y7hhYtM&s=D45vVuai1NqKbXaPiyL_IyC3_nb4RC-eDYCmlpRSVF4&e= . If the e-mail was sent to you in error but does not contain patient information, please contact the sender and properly dispose of the e-mail.