Dear Dr Bruce, Thank you very much for the quick response mri_average -rms will average the 4 volumes for each MEMPRAGE and output one T1 image. The results is four T1 images. How can I average these four T1 images. Can I merge them and use mri_average -rms gain?
-------- Original Message --------
Subject: Re: [Freesurfer] T1 motion and average Local Time: August 15, 2017 6:04 PM UTC Time: August 15, 2017 10:04 PM From: fischl@nmr.mgh.harvard.edu To: John Anderson John.anderso@protonmail.com, Freesurfer support list freesurfer@nmr.mgh.harvard.edu
Hi John
sure, mri_average -rms will take the square root of the sum of squares of the 4 echoes if you want. You could then average them across the MEMPRAGEs if you want
cheers Bruce On Tue, 15 Aug 2017, John Anderson wrote:
Dear Freesurfer experts, I have noisy four MEMPRAGE images each one has four volumes for the same participant. These T1 images were acquired at the same scanning session. I have two question:
- Is there any tool in free surfer to average these images.
- Is the average the images a good idea to reduce noise and improve SNR
- Do you suggest me any solution that can help to reconstruct these noisy
images.
Thank you for any suggestion John
The information in this e-mail is intended only for the person to whom it is addressed. If you believe this e-mail was sent to you in error and the e-mail contains patient information, please contact the Partners Compliance HelpLine at http://www.partners.org/complianceline . If the e-mail was sent to you in error but does not contain patient information, please contact the sender and properly dispose of the e-mail.