good to hear!
On 2/5/19 12:19 PM, Lalonde, Francois (NIH/NIMH) [E] wrote:
External Email - Use CautionHi Doug,
Sorry for the delay in getting back to you. I wanted feedback from the other members of the studies. We all agree that the patch worked wonderfully.
Thanks! François
On 1/24/19, 7:34 PM, "Greve, Douglas N.,Ph.D." DGREVE@mgh.harvard.edu wrote:
The dev version has the same problem :( On 1/24/19 6:37 PM, Lalonde, Francois (NIH/NIMH) [E] wrote: > External Email - Use Caution > > Hi Doug, > > The data I sent was generated using the development version, freesurfer-linux-centos7_x86_64-dev-20180807-df586ca. I downloaded the patch and will rerun the scans using version 6. > > Thanks, > François > > > On 1/24/19, 3:40 PM, "Greve, Douglas N.,Ph.D." <DGREVE@mgh.harvard.edu> wrote: > > Version 6 does not work very well with such high-res data. I created a > patch for the HCP that you can download from here > ftp://surfer.nmr.mgh.harvard.edu/pub/dist/freesurfer/6.0.0-patch/hcp > This works in version 6. Just follow the instructions in the README. > > I ran it on your data, and it looks pretty good. > > > On 1/22/19 12:03 PM, Lalonde, Francois (NIH/NIMH) [E] wrote: > > > > External Email - Use Caution > > > > Hi, > > > > We collected an MP-RAGE scan at .6mm isotropic resolution with the TR > > bumped up to TR=5. Subject motion artifacts were mitigated by using a > > KinetiCor motion correction system. We followed the recommendations > > for processing submillimeter scans described in the FreeSurfer Wiki > > i.e. we added the -cm flag to recon-all and included the mris_inflate > > -n 100 expert option. The attached PDF of the white matter surfaces > > shows that they appear to be underestimated. The surface estimates > > fall short of the actual grey/white matter boundary. Arrows point to > > the most affected areas and the second image is the same as the first > > but without the yellow white matter surface line. FTP is disabled on > > my government computer. Please specify the recipient email if I have > > to transfer the file using FileDrop. Could you suggest other options > > either at the time of scanning or in running recon-all that could help > > better segment the white matter? > > > > Thanks, > > > > François Lalonde, Ph.D. > > > > DNU/HGB/NIMH/NIH > > > > 10 Center Drive, Room 4D18 > > > > Bethesda, MD. 20892 > > > > flalonde@nih.gov > > > > > > _______________________________________________ > > Freesurfer mailing list > > Freesurfer@nmr.mgh.harvard.edu > > https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer > > > _______________________________________________ > Freesurfer mailing list > Freesurfer@nmr.mgh.harvard.edu > https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer > > > _______________________________________________ > Freesurfer mailing list > Freesurfer@nmr.mgh.harvard.edu > https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer _______________________________________________ Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer
Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer