Hi Dr. Fischl
I have a mixture - some of the labels were painted in the MNI305 space (older ones) and the more recent ones are registered to the ICBM152 nonlinear symmetric VI (2006) template.
Best
Trisanna
-- Ph.D. Candidate McGill University Integrated Program in Neuroscience Psychology
On Tue, Apr 5, 2016 at 6:34 PM, Bruce Fischl fischl@nmr.mgh.harvard.edu wrote:
Hi Trisanna
what space are your labels in?
cheers Bruce On Tue, 5 Apr 2016, Trisanna Sprung-Much wrote:
Hi Freesurfer
I have some labels (.mnc) that are painted voxels generated from a
Montreal
Neurological Institute software. I am trying to project the labels onto
the
surfaces generated from recon-all that I applied to the corresponding MRI volumes.
I used mri_vol2surf:
mri_vol2surf --src labels.mnc --out test.mgz --srcreg talairach.auto.xfm --hemi lh
and got the following error:
Error reading inplaneres from talairach.auto.xfm
Do I need a .dat file? If so, how can I attain it? Essentially, what is
the
registration file that I am supposed to be using?
Many thanks!
Trisanna
-- Ph.D. CandidateMcGill University Integrated Program in Neuroscience Psychology
Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer
The information in this e-mail is intended only for the person to whom it is addressed. If you believe this e-mail was sent to you in error and the e-mail contains patient information, please contact the Partners Compliance HelpLine at http://www.partners.org/complianceline . If the e-mail was sent to you in error but does not contain patient information, please contact the sender and properly dispose of the e-mail.