It is more accurate to say that it has the regression coefficients for the HRF. If you use a gamma or spm hrf, then it just has the amplitude (your case). If you use an FIR, then it has the coefficients for each delay in the FIR, which can be assembled into a waveform. I'm not sure what you are looking for if you want something that is equal to the number of time points. What do you want to do with it? doug
Yang Liu wrote:
Hi Doug,
As the freesurferwiki says, the h.nii contains the estimated hemodynamic response at each voxel, along with the standard deviation of the residual error, and h-offset.nii contains a map of the mean value at each voxel. My expectation is that h.nii should have the same dimension as my fmc.nii (the raw time course). For example, my fmc.nii is 90*90*60*256, where 256 is the TRs. But the h.nii is only a 3D array 90*90*60. Why doesn't the h.nii have all the TRs? I also have h0.nii and h0-offset.nii, what are these volume?
Thanks,
Yang
On Tue, Aug 9, 2011 at 1:16 PM, Douglas N Greve <greve@nmr.mgh.harvard.edu mailto:greve@nmr.mgh.harvard.edu> wrote:
You're using a fairly old version of freesurfer. If you have to use this, then use mkanalysis-sess (without the .new). doug Yang Liu wrote: After I run recon-all -version, it shows: "v 1.133.2.57 2009/08/06'. Since we have a lot of scripts for the older version, we kept using the old one. If we don't use mkanalysis-sess.new, what we shall use? Yang On Tue, Aug 9, 2011 at 12:51 PM, Douglas N Greve <greve@nmr.mgh.harvard.edu <mailto:greve@nmr.mgh.harvard.edu> <mailto:greve@nmr.mgh.harvard.edu <mailto:greve@nmr.mgh.harvard.edu>>> wrote: Yes, but don't use mkanalysis-sess.new. Are you not using version 5.X? doug Yang Liu wrote: Hi Doug, Thank you for prompt reply. So I should remove '-gammafit', and add '-fir 4 24' is for mkanalysis-sess.new? Yang On Tue, Aug 9, 2011 at 11:42 AM, Douglas N Greve <greve@nmr.mgh.harvard.edu <mailto:greve@nmr.mgh.harvard.edu> <mailto:greve@nmr.mgh.harvard.edu <mailto:greve@nmr.mgh.harvard.edu>> <mailto:greve@nmr.mgh.harvard.edu <mailto:greve@nmr.mgh.harvard.edu> <mailto:greve@nmr.mgh.harvard.edu <mailto:greve@nmr.mgh.harvard.edu>>>> wrote: If you want a time course, you should use an FIR model, something like "-fir 4 24" to start the time window 4 sec before the stimulus onset and stop it 20 sec after stimulus onset. Do not include -gammafit. doug Yang Liu wrote: Hi all, I want to plot the hemodynamic response of a voxel after my analysis finishes. I hope I can get the hemodynamic response of each voxel for each session, so I can see the statistics by myself. My analysis.cfg is below: -gammafit 0 8 -gammaexp 0.3 -timewindow 40.0000 -prestim 0 -polyfit 2 -TER 2.0000 -autowhiten 40 -nskip 0 -fwhm 0 -extreg mcextreg -nextreg 3 -rescale 1000 After I ran selxavg-sess, I got the following volumes: h0.nii, h0-offset.nii, h.nii, h-offset.nii, rstd.nii, rvar.nii. How can I get a response from these volumes? Yang ------------------------------------------------------------------------ _______________________________________________ Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu <mailto:Freesurfer@nmr.mgh.harvard.edu> <mailto:Freesurfer@nmr.mgh.harvard.edu <mailto:Freesurfer@nmr.mgh.harvard.edu>> <mailto:Freesurfer@nmr.mgh.harvard.edu <mailto:Freesurfer@nmr.mgh.harvard.edu> <mailto:Freesurfer@nmr.mgh.harvard.edu <mailto:Freesurfer@nmr.mgh.harvard.edu>>> https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer -- Douglas N. Greve, Ph.D. MGH-NMR Center greve@nmr.mgh.harvard.edu <mailto:greve@nmr.mgh.harvard.edu> <mailto:greve@nmr.mgh.harvard.edu <mailto:greve@nmr.mgh.harvard.edu>> <mailto:greve@nmr.mgh.harvard.edu <mailto:greve@nmr.mgh.harvard.edu> <mailto:greve@nmr.mgh.harvard.edu <mailto:greve@nmr.mgh.harvard.edu>>> Phone Number: 617-724-2358 <tel:617-724-2358> <tel:617-724-2358 <tel:617-724-2358>> <tel:617-724-2358 <tel:617-724-2358> <tel:617-724-2358 <tel:617-724-2358>>> Fax: 617-726-7422 <tel:617-726-7422> <tel:617-726-7422 <tel:617-726-7422>> <tel:617-726-7422 <tel:617-726-7422> <tel:617-726-7422 <tel:617-726-7422>>> Bugs: surfer.nmr.mgh.harvard.edu/fswiki/BugReporting <http://surfer.nmr.mgh.harvard.edu/fswiki/BugReporting> <http://surfer.nmr.mgh.harvard.edu/fswiki/BugReporting> <http://surfer.nmr.mgh.harvard.edu/fswiki/BugReporting> FileDrop: www.nmr.mgh.harvard.edu/facility/filedrop/index.html <http://www.nmr.mgh.harvard.edu/facility/filedrop/index.html> <http://www.nmr.mgh.harvard.edu/facility/filedrop/index.html> <http://www.nmr.mgh.harvard.edu/facility/filedrop/index.html> The information in this e-mail is intended only for the person to whom it is addressed. If you believe this e-mail was sent to you in error and the e-mail contains patient information, please contact the Partners Compliance HelpLine at http://www.partners.org/complianceline . If the e-mail was sent to you in error but does not contain patient information, please contact the sender and properly dispose of the e-mail. -- Douglas N. Greve, Ph.D. MGH-NMR Center greve@nmr.mgh.harvard.edu <mailto:greve@nmr.mgh.harvard.edu> <mailto:greve@nmr.mgh.harvard.edu <mailto:greve@nmr.mgh.harvard.edu>> Phone Number: 617-724-2358 <tel:617-724-2358> <tel:617-724-2358 <tel:617-724-2358>> Fax: 617-726-7422 <tel:617-726-7422> <tel:617-726-7422 <tel:617-726-7422>> Bugs: surfer.nmr.mgh.harvard.edu/fswiki/BugReporting <http://surfer.nmr.mgh.harvard.edu/fswiki/BugReporting> <http://surfer.nmr.mgh.harvard.edu/fswiki/BugReporting> FileDrop: www.nmr.mgh.harvard.edu/facility/filedrop/index.html <http://www.nmr.mgh.harvard.edu/facility/filedrop/index.html> <http://www.nmr.mgh.harvard.edu/facility/filedrop/index.html> -- Douglas N. Greve, Ph.D. MGH-NMR Center greve@nmr.mgh.harvard.edu <mailto:greve@nmr.mgh.harvard.edu> Phone Number: 617-724-2358 <tel:617-724-2358> Fax: 617-726-7422 <tel:617-726-7422> Bugs: surfer.nmr.mgh.harvard.edu/fswiki/BugReporting <http://surfer.nmr.mgh.harvard.edu/fswiki/BugReporting> FileDrop: www.nmr.mgh.harvard.edu/facility/filedrop/index.html <http://www.nmr.mgh.harvard.edu/facility/filedrop/index.html>