Hi all,
I am using unpacksdcmdir to unpack our data (collected using a Siemens scanner) but running into an error.
I have two questions and hope someone can kindly help me with them:
1. Why can not I successully unpack images for run10?
2. I got the DTI.nii image, the bvecs and bvals for run4 now. Can I use them for my analyses? Seems this run has an error. Does this error matter?
Thank you so much for your help!
Best wishes, Baojuan
The logfile is as follows:
Done scanning Mon Nov 9 19:10:43 EST 2015 ------------------------------------------ 1 localizer ok 512 512 3 1 MR.1.3.12.2.1107.5.2.32.35162.2012120515075082139361714 2 AAScout ok 128 128 128 2 MR.1.3.12.2.1107.5.2.32.35162.2012120515084521701761763 3 T1_MPRAGE_sag ok 256 256 128 1 MR.1.3.12.2.1107.5.2.32.35162.2012120515211411553363371 4 DIFFUSION_HighRes err 128 128 64 70 MR.1.3.12.2.1107.5.2.32.35162.2012120515244054044164212 5 DIFFUSION_HighRes ok 128 128 64 1 MR.1.3.12.2.1107.5.2.32.35162.2012120515335954318286428 6 DIFFUSION_HighRes ok 128 128 64 1 MR.1.3.12.2.1107.5.2.32.35162.2012120515335954396886429 7 DIFFUSION_HighRes ok 128 128 64 1 MR.1.3.12.2.1107.5.2.32.35162.2012120515335954482386430 8 DIFFUSION_HighRes ok 128 128 64 1 MR.1.3.12.2.1107.5.2.32.35162.2012120515335954528786431 9 DIFFUSION_HighRes ok 128 128 64 1 MR.1.3.12.2.1107.5.2.32.35162.2012120515335954607786432 10 DIFFUSION_HighRes ok 128 128 1 64 MR.1.3.12.2.1107.5.2.32.35162.2012120515335954660486433 11 ge_functionals ok 64 64 33 150 MR.1.3.12.2.1107.5.2.32.35162.2012120515373932869186918 unpacking config ------------------ {3 T1 mgz T1.mgz} {4 DTI nii DTI.nii} {10 DTI nii DTI.nii} ----------------------------------- --------------------------------------------------------- Run 3 ----------------------------------------- Mon Nov 9 19:10:43 EST 2015 3 T1 mgz T1.mgz mri_convert /cluster/archive/302/siemens/TrioTim-35162-20121205-150656-604000/MR.1.3.12.2.1107.5.2.32.35162.2012120515211411553363371 /autofs/space/quadra_001/users/baojuan/old_lab_datatset/T1/003/T1.mgz --sdcmlist /autofs/space/quadra_001/users/baojuan/old_lab_datatset/T1/003/flf -ot mgz --nspmzeropad 3 --in_type siemens_dicom --------------------------------------------------------- Run 4 ----------------------------------------- Mon Nov 9 19:10:56 EST 2015 4 DTI nii DTI.nii INFO: this run has an error, but trying anyway mri_convert /cluster/archive/302/siemens/TrioTim-35162-20121205-150656-604000/MR.1.3.12.2.1107.5.2.32.35162.2012120515244054044164212 /autofs/space/quadra_001/users/baojuan/old_lab_datatset/DTI/004/DTI.nii --sdcmlist /autofs/space/quadra_001/users/baojuan/old_lab_datatset/DTI/004/flf -ot nii --nspmzeropad 3 --in_type siemens_dicom --------------------------------------------------------- Run 10 ----------------------------------------- Mon Nov 9 19:11:19 EST 2015 10 DTI nii DTI.nii ERROR: reading /cluster/archive/302/siemens/TrioTim-35162-20121205-150656-604000/MR.1.3.12.2.1107.5.2.32.35162.2012120515335954660486433 tag 28 30