Dear Doug, I uploaded the data by ftp in Windows 10. I hope You can see a tar file. The file's name is HTN_Con_096 and it contains the subject's folder after recon_all. Do You need any other data? All the best Agnieszka
pon., 29 lip 2019 o 22:44 Greve, Douglas N.,Ph.D. DGREVE@mgh.harvard.edu napisał(a):
That is a little strange. Can you tar up the data and upload it to ftp://surfer.nmr.mgh.harvard.edu/transfer/incoming Let me know when it is there and what the file name is
On 7/24/19 4:53 AM, Agnieszka Sabisz wrote:
External Email - Use CautionDear Freesurfer Team, I checked skull stripping and I think it's all right. (see in attachment) The registration looks all right in translational directions but not in scaling. In the attachment you can see the comparison between tkregister view and freeview of the same patient. What may be the reason and how to cope with that? We cannot normalize the volume data to eTIV (as it is not proper), what value should we use instead? Best regards, Agnieszka
sob., 22 cze 2019 o 02:15 Greve, Douglas N.,Ph.D. <DGREVE@mgh.harvard.edu mailto:DGREVE@mgh.harvard.edu> napisał(a):
If the registration looks ok then it probably means that the skull stripping was too aggressive. Have you looked at the skull stripping? On 6/14/2019 1:40 PM, Agnieszka Sabisz wrote:External Email - Use Caution Hi all! We are running FS v.6.0. on a supercomputer operating on Linux. We have two sets of data - one from 1.5T Aera Siemens, second from 3.0T Achieva TX Philips. The T1 images on both scanners have comparable CNR, with an isotropic resolution of 1mm3 each. The recon-all finished with no errors, but in approximately half of the Philips data there is a significant (up to 40%) difference between the brain mask volume and eTIV (no such problem on Siemens). We inspected the Talairach registration (as is pointed that eTIV is calculated upon it) in the mismatched data with: tkregister2 --mgz --s <subject> --fstal --surf orig and in the corrupted data the brain mask and the WM-GM borders align in terms of placement but are of a wrong scale (proportionate to the "brainmask-to-eTIV" difference). What may be the reason and how to cope with that? We cannot normalize the volume data to eTIV (as it is not proper), what value should we use instead? Attached you will find example tkregister2 output screenshots. Best regards, Agnieszka Sabisz _______________________________________________ Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu <mailto:Freesurfer@nmr.mgh.harvard.edu>