It is attached. Finn mentioned it may be due to an event number being missing from the particular subject, which could be possible in the analysis I am doing. _________________________________ Sid Kundu Biomedical Engineering Boston University
On Thu, Mar 1, 2012 at 11:15 AM, Douglas N Greve greve@nmr.mgh.harvard.eduwrote:
It's probably a problem with your design. Can you send me the Xtmp.mat file? doug
Sid Kundu wrote:
Hi Doug,
I created a new first level analysis along with new contrasts and event numbers for a group of subjects I had previously done analyses on. All but one of the subjects finished selxavg3 without error, but one subject gave the following error:
Saving X matrix to /home/sidkundu/freesurfer/** sessions/Heading-TTP/LMV2010_**N19_Heading-TTP/bold/TTP-** analysis-3/Xtmp.mat Error using svd Input to SVD must not contain NaN or Inf.
Error in cond (line 39) s = svd(A);
Error in fast_selxavg3 (line 248) XCond = cond(XtX);
------------------------------**------------
ERROR: fast_selxavg3() failed\n
I looked at the generated Xtmp.mat file and it shows the design matrix X has all zeros in 2 columns, resulting in NaNs in the same columns for Xn, and corresponding NaNs in XtX. I'm wondering what would cause this or why it would only occur for only one subject.
______________________________**___ Sid Kundu Biomedical Engineering Boston University
-- Douglas N. Greve, Ph.D. MGH-NMR Center greve@nmr.mgh.harvard.edu Phone Number: 617-724-2358 Fax: 617-726-7422
Bugs: surfer.nmr.mgh.harvard.edu/**fswiki/BugReportinghttp://surfer.nmr.mgh.harvard.edu/fswiki/BugReporting FileDrop: www.nmr.mgh.harvard.edu/**facility/filedrop/index.htmlhttp://www.nmr.mgh.harvard.edu/facility/filedrop/index.html
The information in this e-mail is intended only for the person to whom it is addressed. If you believe this e-mail was sent to you in error and the e-mail contains patient information, please contact the Partners Compliance HelpLine at http://www.partners.org/**compliancelinehttp://www.partners.org/complianceline. If the e-mail was sent to you in error but does not contain patient information, please contact the sender and properly dispose of the e-mail.