Hi,
In the FS-FAST analysis stream (dev environment), I used autoreg-sess command as follows:
autoreg-sess -s mvp022106 -df df.txt
It successfully generated a register.dat file in the bold directory. Then I used tkregister-sess as follows:
tkregister-sess -s mvp022106 -df df.txt -rsd t1epi
When tkregsiter window comes, the structural volume (anatomical T1) is OK but t1epi volume is completely corrupted. However, running tkregister-sess with '-rsd t1epi' generates another register.dat file in the directory above the bold directory. When I use this register.dat file in the tkregister-sess command, t1epi volume looks fine and almost in the appropriate location as T1 volume.
I also tried spmregister-sess instead of autoreg-sess:
spmregister-sess -s mvp022106 -df df.txt -fsd bold
A register.dat file is generated by this command in the bold directory. Then I used tkregister-sess as follows:
tkregsiter-sess -s mvp022106 -df df.txt -fsd bold
In the tkregsiter window, the functional volume looks fine but it is largely displaced. I could finally register it manually.
I might do something wrong with autoreg-sess and spmregister-sess or is there a bug for these commands?
Thanks, Reza
******************************** Reza Rajimehr, MD
NMR Athinoula A. Martinos Center Department of Radiology Massachusetts General Hospital (MGH) Building 149, 13th St. Charlestown, MA 02129
Email: reza@nmr.mgh.harvard.edu ********************************