Thank you Douglas for your suggestions!
If I use mris_anatomical_stats, would I perform the following procedure?
- To run "mri_label2label" to all the subjects of my comparison - To run mris_anatomical_stats. I would obtain the volume of the labels in each subject - Mean volume of all the subjects
I have tried to map the label to fsaverage and ru run mris_anatommical_stats but I have an error and I am not sure if it is correct.
Thanks again, Yolanda
2011/7/26 Douglas N Greve greve@nmr.mgh.harvard.edu
Hi Yolanda, don't use thmax (it will exclude everything with a sig>7 -- not what you want I assume). That command otherwise looks right, but it won't correct for multiple comparisons. You can run mris_anatomical_stats on the output label to give you the stats you want.
doug
Yolanda Vives wrote:
Dear freesurfers,
I would like to obtain the cluster size (in mm3) and coordinates of the maxima of a cortical volume comparison using mri_surfcluster.
mri_surfcluster --in $PATH/control_cronic_dones_** right_volume/rh-Diff-control-**cronic-Intercept-volume/sig.**mgh --hemi rh --subject fsaverage --thmin 2 --thmax 7 --sign pos --surf pial --no-adjust --o ./concro --ocn ./cluster_number --olab ./grouplabel_concro --sd $SUBJ_DIR --sum ./concro_sum
Would it be correct.
Regarding the results that I obtain, I have some questions:
- Which surface do I have to load? pial, orig?
- In the summary file, the cluster size is given in mm2, is it possible to
obtain it in mm3 (I am analysing cortical volume)?
Thank you for your help, Yolanda
------------------------------**------------------------------**
______________________________**_________________ Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu https://mail.nmr.mgh.harvard.**edu/mailman/listinfo/**freesurferhttps://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer
-- Douglas N. Greve, Ph.D. MGH-NMR Center greve@nmr.mgh.harvard.edu Phone Number: 617-724-2358 Fax: 617-726-7422
Bugs: surfer.nmr.mgh.harvard.edu/**fswiki/BugReportinghttp://surfer.nmr.mgh.harvard.edu/fswiki/BugReporting FileDrop: www.nmr.mgh.harvard.edu/**facility/filedrop/index.htmlhttp://www.nmr.mgh.harvard.edu/facility/filedrop/index.html
The information in this e-mail is intended only for the person to whom it is addressed. If you believe this e-mail was sent to you in error and the e-mail contains patient information, please contact the Partners Compliance HelpLine at http://www.partners.org/**compliancelinehttp://www.partners.org/complianceline. If the e-mail was sent to you in error but does not contain patient information, please contact the sender and properly dispose of the e-mail.