35% sounds high to me. Did you actually check the registration
You can always load the the fMRI as an overlay in freeview, try tksurferfv subject lh inflated -ov fmri-sampled-on-lh.mgz Also, please include command lines you used
On 11/21/19 10:03 AM, An wrote:
External Email - Use Caution
Hi there,
I want to map the intensities of the fMRI 4D volumes onto its surface in order to get the functional values on each vertex in each frame.
I have done the following steps for achieving this:
- ran recon-all on its anatomical volume.
- register the fMRI series with the anatomical volume by using
bbregister. 3. assign values from volumes to each surface vertex through the command mri_vol2surf.
I have got a result of mapping the 4D volumes intensities onto its surfaces but there are 35.5% vertices assigned 0 value in every time frame.
I am wondering is the ratio reasonable and how could I improve the result? I guess resolution would be one of reasons causing the high 0 value ratio, my fMRI data is 2mm^3 and anatomical data is 1mm^3.
Many thanks for your help.
Best, An