Hi Kasper
what was your input volume? The .02sec change in TR won't mean anything, although it is a bit surprising to see, as is the fact that the other parameters (flip angle, TE, etc...) don't seem to be preserved. We usually read those right out of the dicom files if that is what you used as input. Not sure why we would preserve the TR but not the other parameters.
cheers Bruce
On Sat, 10 Oct 2015, Kasper Jessen wrote:
Dear Freesurfer group,
When looking through the log after running recon-all, i have noticed two different errors in the logs. The one being about 'volumes differ in acquisition parameters' and the other 'Image geometries differ across time, maybe due to aquisition changes?'.
Volumes differ in acquisition parameters v1acq fa=0.000000 tr=10.032000 te=0.000000 ti=0.000000 v2acq fa=0.000000 tr=10.012000 te=0.000000 ti=0.000000 WARNING: Image geometries differ across time, maybe due to aquisition changes? This can potentially bias a longitudinal study! Will continue in 10s.
What do the above errors mean and is it something we should be worried about?
Best regards, Kasper Jessen MD, PhD Student