External Email - Use Caution
Thank you!
Il giorno mar 18 dic 2018 alle ore 11:43 Bruce Fischl < fischl@nmr.mgh.harvard.edu> ha scritto:
Hi Maurizio
the orig.mgz has been converted to 1 byte/pixel and 256^3 1mm isotropic. You can use mri_convert to go back to your original data space via:
mri_convert -rl orig/001.mgz <input volume> <output volume>
cheers Bruce
On Tue, 18 Dec 2018, Maurizio Bergamino wrote:
External Email - Use CautionHello,I am trying to run a VBM analysis by using the white matter and
the grey matter masks from
Freesurfer, because, often, other tools are not able to calculate a
correct white matter and grey matter
masks. When I have these masks, I have to apply them to my original T1 images.
However, the original T1 is in
different space. I can resample the ROIs (WM and GM) in order to apply
them to my original T1, but my
question is: Can I use the orig.mgz from Freesurfer as my T1 for VBM, or does it have
different intensity from my real
T1 acquisition?
Thanks, Maurizio
Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer