Hi Frank, we'll need a lot more detail. Are you doing all of this in FreeSurfer? What are your command lines? How are you evaluating whether volumes are flipped? doug
Léoné wrote:
Dear all,
I must be missing something really obvious, but it seems my brains are flipped. What I do:
- I have a highres structural scan, nii file format
- I convert it to a surface using recon-all
- Coregister the highres structural to the functional scan, so it is in the voxel size and orientation as the functional scans
- I try to bbregister the coregistered and resliced T1 with the surface
But then: hey, it doesn't fit, my low-res T1 is flipped compared to my y surface, hence to my original T1. So is it indeed true that my T1 might have been flipped? If so, does it make a wrong assumption on neurological vs radiological convention, or what is going on?
Thanks in advance,
best, Frank
Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer