Hi Alen,
check the accuracy of the intensity normalization (T1.mgz) and the talairach transform (talairach.xfm).
cheers Bruce On Wed, 23 Dec 2009, Alen Zamanyan wrote:
FreeSurfer Support:
I am trying to execute MRI_Watershed and receive the following error:
White matter intensity 0 is lower than CSF intensity 17. Please examine input images. Will terminate ...
MRIstripSkull failed.
What could be wrong with the input volume? How can I fix this? Any ideas?
Thanks, Alen