Hi Julia, this is a bug. We've fixed it in our development version, but for you there are a few option. One is that you can just get the value from aseg.stats (asegstats2table). Or you can run recon-all with these flags -talairach -parcstats -parcstats2 -parcstats3
On 12/29/2020 7:34 AM, Julia Lam wrote:
External Email - Use Caution
Dear all,
I received values of 0.0 on variables BrainSegVolNotVent and eTIV when running aparcstats2table on volumes where I've added control points. However, when aseg2stats was used, the variable EstimatedTotalIntraCranialVol was different from 0 on all, including the edited ones. Why is that?
I've attached the logfile from one of the subjects where I used control points.
I really appreciate any help you can provide.
Yours sincerely Julia Lam
_______________________________________________ Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edumailto:Freesurfer@nmr.mgh.harvard.edu https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer