Hi all,
I've been having two variants of problems with wm.mgz, using version5.1. One can be seen in the attached screenshot FI137 - areas that are not white matter are designated as "white matter hypointensities" on wm.mgz, and create problems with both surfaces. This has happened in a number of our subjects, in multiple locations throughout each brain. Is this something we just need to delete manually on each subject, or is there a more efficient way to deal with this?
The second is seen in the screenshots of MP860 wm. An area that is not white matter, and is not designated as white matter on wm.mgz, is still created as a white matter surface. This hasn't happened as often as the above, but we don't know how to get rid of an inaccurate wm surface if it's not on wm.mgz.
Thanks for your help, Nicole