External Email - Use Caution
Thanks Dr. Greve. That works, but both white.K and white.H are giving me very different output values.
For example, for first few subjects I get: -0.00237 -0.00450 -0.00204 0.00113 -0.00228 -0.00958 -0.00314 0.00180 -0.00452 if I use white.K -0.05809 -0.05799 -0.06457 -0.07254 -0.07208 -0.05023 -0.06044 -0.09338 -0.09178 if I use white.H
Can you please tell me the difference between white.K and white.H conceptually and mathematically?
On Wed, Dec 19, 2018 at 2:27 PM Greve, Douglas N.,Ph.D. < DGREVE@mgh.harvard.edu> wrote:
something like --meas white.K or white.H
On 12/19/2018 04:23 PM, Martin Juneja wrote:
External Email - Use CautionHi,
Just like volume, I have "Folding Index" measures saved in lh/rh.aparc.stats files for each subject.
If I am using mris_preproc *--meas volume* --out CV/lh.CV.mgh command to concat cortical volume files from all subjects, then how can I use this command for "folding index" output file?
Any help will be really appreciated.
Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer
Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer